GNP-P-CO
Gas type
Carbon Monoxide (CO)
Carbon Monoxide (CO)
Technology
Electrochemical / NDIR
Electrochemical / NDIR
Measuring range
0...40000 ppm
0...100 %vol
0...40000 ppm
0...100 %vol
Measuring method
Pipeline
Pipeline
Accuracy
< 2.0 % of full scale
< 2.0 % of full scale
Temperature resistance
-20...+60 °C
-20...+60 °C
Life expectancy
1...3 years (ppm), 5...10 years (%vol)
1...3 years (ppm), 5...10 years (%vol)
Supply voltage
24 Vdc
24 Vdc
Output signal
4-20 mA
4-20 mA
Protection
Explosion proof
Exd II CT6
Exd II CT6
Data sheet (English)
pdf data_GNP-P-CO